<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-28 12-28-32
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 68 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.9 kHz -66 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19000 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,3 dBr 1,57 dBr 4,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia Nro 2 C-Molli Ylosnousemussinfonia: II. Anda...(Mahler)"
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,0053 Acquired: 2025/02/28 12.27.29 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,6 dBr MIN: -1,3 dBr AVE: 1,57 dBr % above 12,2 dBr: 0,0 Last value: 1,1 dBr (2025/02/28 12.27.29) 12.14 12.16 12.18 12.20 12.22 12.24 12.26 -2 0 2 4 Pm [dBr]